The measurement data is recorded using a five-hole probe. These are used to record the magnitude and direction of the velocity vector at a local point within a flow field. A miniature five-hole probe with a spherical head is used. The probe head has a diameter of 2 mm and the pressure holes each have a diameter of 0.3 mm. The measurements were carried out at a Mach number of 0.13.